Abstract

The problem of using an elastic organosilicon polymer (“aquapolymer”) as an immersion medium for providing a stable acoustic contact between a test object and a piezoprobe in the process of automated ultrasonic testing of objects with rough surfaces is considered. The use of an “aquapolymer” allows one to decrease the consumption of water during ultrasonic testing. Flaw images were reconstructed using a modification of the SAFT method, which takes the profile of a test object into account; this allows improvement of the image quality. An algorithm for obtaining information on the profile of the surface of a test object and taking this profile into account during reconstruction of flaw images with the SAFT method is proposed. Model experiments yielded flaw images with the refraction of beams on a rough surface taken into account.

Full Text
Paper version not known