Abstract

The mechanical limit of ultrasonic transducers is associated with the fracture, nonlinearities, and fatigue strength of the different materials and thus is directly related to the distribution of stresses over the structure. The static case corresponds generally to the design of depth transducers and prestressed ceramic stacks. The dynamic case concerns high‐power sonar transducers, as well as macrosonics. For several transducers, the stress field has been computed with the help of a finite element modeling, using the ATILA code [J. N. Decarpigny et al., J. Acoust. Soc. Am. 78, 1499 (1985)]. This paper describes such an analysis in the case of an axisymmetrical length expander transducer and a flexural shell sonar transducer [B. Hamonic et al., J. Acoust. Soc. Am. Suppl. 1 80, S26 (1986)]. The static stresses distribution is found when a mechanical bias is applied and maximum dynamic stress zones are identified at several frequencies, using a classical fatigue criterion. Measurements with strain gauges di...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.