Abstract

An improved model for calculating the current distribution in salient-pole synchronous machines with internal faults or missing coils in the stator winding is established using the multi-loop method. For this purpose, a good knowledge of the time-depending inductances is necessary. In this paper, a calculation method is presented to determine the inductances of the damper winding, the mutual inductances between the field winding and the damper winding as well as the mutual inductances between the stator coils and the damper winding of a salient pole synchronous machine. The method presented here considers the analytical calculation of the magnetic flux density based on the magnetomotive force and the time-depending air-gap permanence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.