Abstract

The influence of the boiler unit load on the area of heterogeneous reactions of the process of catalytic flue gas purification is considered. The optimal geometric characteristics of the neutralizer monolith were determined when the steam capacity of the TGME-464 boiler unit varied from 220 to 500 t/h. The calculations were performed using a mathematical model for the conditions of the operating power equipment. The optimal size of the unit cell of the catalyst block is determined in a wide range of boiler load regulation. The data obtained as a result of the study formed the basis for designing a sample of an industrial neutralizer of toxic flue gas components without the introduction of an external reagent.