Abstract

The cryolite ratio (CR) is an important parameter for the electrolyte in aluminum reduction cells. The measurement method for the CR of the KF-NaF-AlF3 system acid (CR < 3) electrolyte by means of electrical conductivity was initially developed, and the formula for calculating the CR was deduced. This method has the advantages of simple operation and high precision. In addition, the relative standard deviations (RSD) of the measurement are < 1.2 pct, and the analysis error of the NaF or KF content has little effect on the determination of the CR.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.