Abstract

A gas chromatographic procedure with headspace analysis and flame-ionization detection is described for the determination of the chlorofluorocarbon substitute 1,1,1,2-tetrafluoroethane (HFA-134a). A 0.5-2 ml sample of heparinized whole blood from a laboratory animal or human is added directly into a presealed headspace vial from which an equivalent volume of air has been removed. The internal standard 1,1,2,2-tetrafluoroethane is added and the sample frozen until analysis. Chromatographic separation is achieved using a PoraPlot Q porous-layer capillary column. The analytical range is 5.8-3298 ng/ml when 2-ml human blood samples are used. The concentration range of the calibration curve can be easily adapted to accommodate the concentrations expected in either pharmacokinetic or toxicokinetic studies. Automation of the assay permits the maximum number of samples to be processed in a day.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.