Abstract

We present a method for the quantitative determination of the Agidol-1 antioxidant additive in fuels for jet engines in concentrations of 0.001–0.006 wt % by HPLC after its preconcentration by extraction with methanol. The ratio of fuel-to-methanol-to-water in extraction is optimized. Chromatographic separation was performed on a Kromasil C18 reversed-phase column, upon isocratic elution with a mixture of acetonitrile–water (60 : 40) and UV detection at a wavelength of 210 nm. The data were processed using the Turbochrom software.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have