Abstract
Chemically modified mesoporous silica material (SBA-15) was used for the construction of Tl(I) selective carbon paste electrode. The best response was found with the electrode containing 10% modifier as electrode material. The electrode has a lower detection limit of 6.0 × 10−9 M in a working concentration range of 1.0 × 10−8–1.0 × 10−1 M. The selectivity coefficient calculated by match potential method (MPM) shows the high selectivity of electrode towards Tl(I) over other tested ions. The electrode was successfully applied as an indicator electrode for the titration of 0.01 M TlNO3solution with standards EDTA solution and for sequential titration of mixture of different anions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.