Abstract

A rapid, sensitive, and accurate solid-phase extraction method was developed for the measurement of 10 N-nitrosoamino acids (NAAs) in cured meat products. In the procedure, the comminuted meat was mixed with sulfamic acid and Celite, and then added to a glass column containing anhydrous sodium sulfate. The column was washed with pentane, and the NAAs were eluted with ethyl acetate. The eluate was concentrated, then derivatized with diazomethane followed by acetic anhydride-pyridine reagent. The NAA methyl esters and their acylated hydroxy derivatives were separated by gas chromatography on a DB-5 fused silica capillary column and quantitated with a thermal energy analyzer, a chemiluminescence detector specific for nitric oxide derived from the thermal denitrosation of nitrosamines. Recovery of 10 of the NAAs exceeded 75% at the 10 ppb level. The method is applicable to a wide range of cured meat products.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.