Abstract

We have developed a method for measurement of temperature in glass products with the following features: (1) non-contacting, (2) real time, and (3) through-thickness. The method is based on fluorescence emission. Many glass products include Fe 2O 3 as an additive in various amounts. Ferric (Fe 3+) and ferrous (Fe 2+) ions absorb light in the ultraviolet and infrared parts of the spectrum. Absorption of light by iron ions in glass results in a predictable fluorescence emission. The emission in turn depends on the glass temperature, and this dependence is the basis for our method of measuring temperature. We have measured the fluorescence emission lifetimes in several commercial automotive glass samples over a temperature range from 25°C to 550°C (about 300–825 K). Imaging the fluorescence emission from glass samples onto a segmented photomultiplier tube provided spatially resolved measurements. A simple model that relates the temperature to the fluorescence lifetime has been developed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.