Abstract

The procedure of deriving flame temperature and major species concentrations by fitting measured Raman spectra in hydrocarbon flames is described. The approach simplifies the calibration procedure to determine temperature and major species concentrations from the measured Raman spectra. The calculations of the Raman spectra are performed using data online positions and cross sections from the current literature. Utilizing all spectral information for deriving temperature and major species concentrations substantially increases accuracy, while interferences can easily be detected and filtered out of the measured spectrum. Temperatures from the separate Raman spectra of N2, H2O, O2, CO2 and CO are systematically compared with each other over the span of more than 1,700 K. The agreement between them is generally better than 100 K. The developed procedure also allows us to determine the mole fractions of the major species with absolute accuracy of ±10 %.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.