Abstract

A method has been developed for confirmation and quantitation of ten sulfonylurea herbicides (nicosufuron, thifensulfuron-methyl, metsulfuron-methyl, sulfometuron-methyl, chlorsulfuron, ethametsulfuron-methyl, tribenuron, bensulfuron-methyl, pyrazosulfuron-ethyl and chlorimuron-ethyl) in water samples. Herbicides were extracted from water by off-line solid-phase extraction (SPE). Different types of absorbents were evaluated: silica-based ODS-C18 and two polymeric sorbents, Cleanert HXN and Oasis HLB. Analyte determination and quantitation was performed by liquid chromatography with electrospray mass spectrometry (LC-ESI-MS) instrumentation, equipped with ion trap mass filter. Confirmatory analysis was carried out by LC/MS/MS. MS data acquisition was performed by a single or two-ion extracted ion monitoring program. The ten herbicides were measured in fortified tap water. Average recoveries of the nine analytes (except for tribenuron) from water samples were in the range of 77–109%, and the RSD ranged from 0.3 to 14.5%. The limit of detections (LODs) varied from 6 to 34.8 ng/L.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.