Abstract

Sulfamethazine (SMZ) and trimethoprim (TMP) are antibacterials used in veterinary practice. This paper describes a method for their determination in veterinary liquid feed premixes that is based on liquid chromatography with diode array detection. Gradient elution with methanol and ammonium acetate achieved excellent separation of the two analytes within 15 min without any interference from the matrix. Absorbance of the column effluent was monitored at 264 nm for SMZ and at 230 nm for TMP. Detailed analyses of the uncertainties of determinations afford estimated expanded uncertainties of, respectively, 0.2 and 0.1 w/v % for typical SMZ and TMP concentrations of 10.7 and 2.1 w/v %, respectively. At the lower end of the calibrated range of the method, the dominant source of uncertainty is the preparation of standards and the construction of the calibration line.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.