A rapid isotachophoretic method was used for the simultaneous determination of sodium octanoate and N-acetyl- dl-tryptophan, which are used for the stabilization of human serum albumin (HSA) solution. The methods of external calibration and standard addition were used with conductimetric and spectrophotometric detection. The operational system applied is suitable also for the simultaneous determination of organic acids present in HSA solution without further treatment.