Abstract

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The effect of experimental variables, such as breakthrough volume with different concentrations of PAHs, type and volume of solvents for elution step were studied in SPE using C 18 cartridge as sorbent. Different solvents (methanol, hexane and chloroform) were used for elution step in SPE. The best solvent for elution was hexane with volume of 3 ml, recoveries over 82 % and relative standard deviations lower than 6 %. Detection limits ranging from 0.02 to 0.14 µgml -1 were obtained for different PAHs using HPLC method. Concentration of PAHs in the caspian seawater were 0.34 to 14.11 ngml -1 .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.