Abstract

A sensitive and specific method for the simultaneous determination of the unchanged drug (solifenacin) and its major metabolite (M1, 4 S-hydroxy solifenacin) in rat plasma was developed and validated. Both solifenacin and M1 were extracted from rat plasma by a two-step liquid–liquid extraction and analyzed by semi-micro HPLC with UV detection at an absorbance wavelength of 220 nm. The chromatographic separations were performed on a TSKgel ODS-80Ts (5 μm, 150 mm × 2.0 mm i.d.) reversed-phase column with a mobile phase of 0.1 M phosphate buffer (pH 3.0):acetonitrile (71:29, v/v). The intra-day precision (expressed as coefficient of variation, CV) ranged from 0.4% to 1.7%, and the accuracy (expressed as relative error, RE) ranged from −5.2% to 2.0% for solifenacin. The corresponding precision ranged from 1.3% to 3.2%, and accuracy ranged from −4.0% to 8.6% for M1. The lower limit of quantitation for both solifenacin and M1 was 2 ng/ml when 1 ml of plasma was used. No endogenous interference was observed in rat plasma.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call