Abstract

The study determined some air quality parameters in Zaria and environs by monitoring the level of carbon monoxide, Sulphur (iv) oxide, Nitrogen (iv) oxide, and Hydrocarbon at five locations within the study area for eight weeks. The concentration of the gases was measured in part per million (ppm) using automatic hand held Crowcon- Gasman Detection Instrument (model number EExias IIC T3/T4 and EExia IIC T3/T4 with certificate number Ex 93Y 2078 X and Ex 93C 2069 X respectively) manufactured by Crowcon Detection Instruments Ltd England that employs a catalytic beard sensor for methane gas and electrochemical sensors for the other gas measurements. The average concentrations of the gaseous emission were ranged: CO (2.78 – 33.48 ppm) which was recorded to be above the National Ambient Air Quality Standard (NAAQS) threshold range of 10 – 20 ppm, NO2 (0.006 – 0.052 ppm) was found to be within the NAAQS limit of 0.04 – 0.06 ppm, SO2 (0.003 – 0.037 ppm) was within the NAAQS limit of 0.01 – 0.1 ppm and HC (0.005 – 0.038 ppm) which was found to be lower than the NAAQS limit of 0.05 ppm. The results indicate that the concentration of gaseous pollutants in the study area do not pose any major threat to the environment and humans.Keywords: Air, Pollution, Carbon monoxide, Sulphur (iv) oxide, Nitrogen (iv) oxide, and Hydrocarbon

Highlights

  • The world's urban pollution has risen quicker over the last 5 centuries (27% per year) than the complete population (1.8% per year) and is anticipated to increase to as much as 5 billion by 2030. (Parrish et al, 2011)

  • The research aimed at assessing the level of air pollution in the selected areas in comparison with maximum allowable limits recommended by the national ambient air quality standard (NAAQS)

  • The concentrations of carbon (II) oxide (CO) at the experimental sites were higher than the NAAQS threshold range of 10 – 20 ppm except for Chindit Junction and Polo field which were found to be lower or within the ranges in the morning and evening hours

Read more

Summary

Introduction

The world's urban pollution has risen quicker over the last 5 centuries (27% per year) than the complete population (1.8% per year) and is anticipated to increase to as much as 5 billion by 2030. (Parrish et al, 2011). The concentrations of CO at the experimental sites were higher than the NAAQS threshold range of 10 – 20 ppm except for Chindit Junction and Polo field (used as the control site) which were found to be lower or within the ranges in the morning and evening hours.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.