Abstract
Aromatic diamine hydrochlorides have been determined in the presence of different amounts of hydrochloric acid by acid-base titration followed potentiometrically, by linear sweep voltammetry, by differential pulse voltammetry and also by direct DPV measurement. Tests on simulated and production samples have shown that the best results are obtained by using DPV at a mercury electrode, because of its good resolution, which makes it possible to achieve good accuracy (error < - 1 %) and good precision (rsd 1.5%) at 0.1 M levels. Moreover, it has the advantage that neither preliminary treatment of the sample nor a trial titration is required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.