Abstract

CdZnTe detector was used to monitor the radioactivity at several locations of primary heat transport (PHT) system of the Tarapur Atomic Power Station-III & IV reactor during shut down as well as operating condition of the reactor. Dose measurements at the same locations were also carried out using a teletector. MCNP code was used to simulate the detector efficiency for the required counting geometry. The efficiencies were then used to convert the experimental count rates (cps) to corresponding activity concentration (Bq/mL) of different radionuclides in coolant water. The total dose rates in these locations were also calculated by summing up the simulated dose rates of individual γ ray energy. The simulated and the measured total dose rates were found to be in reasonably good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.