Abstract

A reliable and rapid method is described for the determination of prednisone and prednisolone in human serum by high-performance liquid chromatography, using a Zorbax-SIL column with dichloromethane-ethanol (92.5:7.5) as eluent, with UV detection at 254 nm. Metabolites and endogenous hydrocortisone did not interfere with the determination of prednisone and prednisolone. The alteration of corticosteroid concentrations in serum from patients with chronic liver diseases was studied following a single oral administration of prednisone or prednisolone (30 mg). The proposed method showed good separation of several corticosteroids and was time-saving, suitable and reliable for the routine analysis of corticosteroids in human serum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.