Abstract

Polycyclic aromatic hydrocarbons (PAHs) were determined in soil samples from forty different locations in Vojvodina. The samples were Soxhlet extracted cleaned-up and analyzed using gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode (SIM). Each PAH was separately quantified using an eight-point calibration of mixed standard solutions in the range between 0.25 and 10 ?g/cm3. The sum of the 16 US Environmental Protection Agency PAHs analyzed in the soil samples varied from 0.043 to 1.362 mg/kg of dry soil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.