Abstract

An alternative procedure to the classical fire assay method for determining Pt and Pd in sulfide ores, concentrates, and furnace mattes is presented. A suitable amount of sample is digested with aqua regla and filtered and any remaining gangue is digested with a mixture of HF and HClO/sub 4/. The solution is filtered and the residue fused with sodium peroxide granules. The fused salts are dissolved in a dilute HCl acid solution and all three solutions combined. The resultant solution is passed through a Bio-Rad AG 50W-X8 cation exchange resin in the H/sup +/ form. The chlorocomplex anions of Pt and Pd are not retained by the cation exchange resin while the base metal cations are efficiently removed from the eluent. Pt and Pd concentrations are subsequently determined with an inductively coupled plasma (ICP). Preliminary experiments showing the method's potential expandability to Au are included.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.