Abstract
ABSTRACTA method for the precise and accurate determination of phosphorus in crude oil and middle distillate petroleum products was developed using inductively coupled plasma–optical emission spectrometry to rapidly determine phosphorus as a control method. The presence of phosphorus is undesirable in petrochemical products as it complexes with other metals generating residues that interrupt normal operation of refineries. The presence of phosphorus may be due to some anti-fouling additives or the crude oils processed. Consequently, it is necessary to control the phosphorus present at trace levels in the crude oil and in process streams that present various densities and viscosities. The instrumental power, nebulizer flow, pump rate, read time, and the sample preparation conditions were optimized. The desired level of quantification for the petrochemical industry was achieved allowing the simultaneous analysis of diverse liquid petroleum products.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.