Abstract

Application of hollow fiber-based electromembrane extraction was studied for extraction and quantification of phenytoin from exhaled breath condensate (EBC). Phenytoin is extracted from EBC through a supported liquid membrane consisting of 1-octanol impregnated in the walls of a hollow fiber, and into an alkaline aqueous acceptor solution inside the lumen of the fiber. Under the obtained conditions of electromembrane extraction, that is, the extraction time of 15 min, stirring speed of 750 rpm, donor phase pH at 11.0, acceptor pH at 13.0, and an applied voltage of 15 V across the supported liquid membrane, an enrichment factor of 102-fold correspond to extraction percent of 25.5% was achieved. Good linearity was obtained over the concentration range of 0.001-0.10 µg/mL (r2 = 0.9992). Limits of detection and quantitation were 0.001 and 0.003 µg/mL, respectively. The proposed method was successfully applied to determine phenytoin from EBC samples of patients receiving the drug. No interfering peaks were detected that indicating excellent selectivity of the method. The intra- and interday precisions (RSDs) were less than 14%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.