Abstract
A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The SiO2/PDMS coating was prepared by sol-gel method and characterized with respect to morphology and specific surface area. The results of field-emission scanning electron microscope (FE-SEM) and N2 adsorption-desorption as well as phenol adsorption experiments denoted that SiO2/PDMS has larger surface area and better adsorption capacity than commercial PDMS. The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time. More than 75% of phenol desorption efficiency could be kept even after 50 cycles of extraction, indicating the high stability of the SiO2/PDMS coated stirring bar. Approximately 0.16 mg/L 2, 5-dimethylphenol (2, 5-DMP), which was 34-fold more toxic than phenol, was detected in water through HPLC-FTIR. However, 2, 5-DMP could be oxidized to 5-methy-2-hydroxy benzaldehyde after disinfection in drinking water treatment process. Therefore, the proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment.
Highlights
A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration
The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time
Different from the net-like surface of PDMS coating, the surface of SiO2/PDMS coating was packed by globular structure, possibly leading to an increase of the surface area
Summary
A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment. The purpose of this study is to prepare a novel nano-SiO2/PDMS coating and to develop a new method of nano-SiO2/ PDMS-SBSE coupled with HPLC-FTIR for the determination of phenols isomers in water. The parameters affecting the extraction capacity of phenols by nano-SiO2/PDMS-SBSE were investigated, including adsorption time, flow rate, ion strength, desorption solvent and time, and the analytical performance of the proposed method (SiO2/PDMS-SBSE-HPLC-FTIR) was evaluated. The developed method was applied to determine phenols isomers in water, and its possible utilization in water treatment plants was examined
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.