Abstract

A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The SiO2/PDMS coating was prepared by sol-gel method and characterized with respect to morphology and specific surface area. The results of field-emission scanning electron microscope (FE-SEM) and N2 adsorption-desorption as well as phenol adsorption experiments denoted that SiO2/PDMS has larger surface area and better adsorption capacity than commercial PDMS. The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time. More than 75% of phenol desorption efficiency could be kept even after 50 cycles of extraction, indicating the high stability of the SiO2/PDMS coated stirring bar. Approximately 0.16 mg/L 2, 5-dimethylphenol (2, 5-DMP), which was 34-fold more toxic than phenol, was detected in water through HPLC-FTIR. However, 2, 5-DMP could be oxidized to 5-methy-2-hydroxy benzaldehyde after disinfection in drinking water treatment process. Therefore, the proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment.

Highlights

  • A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration

  • The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time

  • Different from the net-like surface of PDMS coating, the surface of SiO2/PDMS coating was packed by globular structure, possibly leading to an increase of the surface area

Read more

Summary

Introduction

A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment. The purpose of this study is to prepare a novel nano-SiO2/PDMS coating and to develop a new method of nano-SiO2/ PDMS-SBSE coupled with HPLC-FTIR for the determination of phenols isomers in water. The parameters affecting the extraction capacity of phenols by nano-SiO2/PDMS-SBSE were investigated, including adsorption time, flow rate, ion strength, desorption solvent and time, and the analytical performance of the proposed method (SiO2/PDMS-SBSE-HPLC-FTIR) was evaluated. The developed method was applied to determine phenols isomers in water, and its possible utilization in water treatment plants was examined

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.