Abstract

Ozone removal by 16 aged (older than 1-120 months) but unused building products or materials was studied in a test system that included the field and laboratory emission cell (FLEC). The ozone removal was studied at 50 +/- 1 ppb ozone, a relative humidity of 50 +/- 5%, a temperature of 21 +/- 2 degrees C, and an air flow rate of 900 +/- 10 mL min(-1) through the FLEC (air velocity ca. 3 cm s(-1)). The ozone removal increased rapidly during the first 1-2 min and either remained at a constant level or decreased asymptotically to reach a steady state-like value. The ozone removal profiles for a given material showed good repeatability during replicate experiments. Ozone deposition velocities for the building products were calculated to be between 0.0007 cm s(-1) (lacquered ash) and 0.8 cm s(-1) (unpainted gypsum board).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.