Abstract

A gas-liquid chromatographic (GLC) procedure with p-toluenesulfonamide (p-TS) as an internal standard is used to determine o-toluenesulfonamide (o-TS), a major impurity in artificial sweetening substances containing saccharin. Although p-TS can itself occur as an impurity in samples, it is usually absent or present in very small amounts; the highest quantity found in 13 samples analyzed was about 1 ppm. The presence of appreciable amounts, however, would not pose a problem with the GLC procedure. Recoveries of standard o-TS added at various levels were approximately 90%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.