Abstract

A low-temperature clean-up method for residue determination was developed and validated for 14 organophosphorus pesticides in soybean oil, peanut oil and sesame oil by gas chromatography with flame photometric detector (GC-FPD). A different matrix influenced the response and retention time of pesticides. Hence matrix-matched calibration standards were used to counteract the matrix effect. The pesticide responses in blank samples of soybean oil, peanut oil and sesame oil were within the linear range of 0.02–1 mg kg−1 and the correlation coefficients were higher than 0.9989. Average recoveries obtained from different oil samples at three fortified levels were higher than 50% with relative standard deviations (RSDs) of less than 15%. The limit of detections (LODs) of studied pesticides ranged from 2 to 5 μg kg−1. Thirty-nine commercial samples were analyzed, and the results were confirmed by gas chromatography–mass spectrometry (GC–MS) in selective ion monitoring (SIM) mode.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call