Abstract
A fast and simple procedure for the analysis of aqueous samples by on-line membrane disk extraction and capillary gas chromatography (GC) is presented. As an example, organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.2 mm diameter extraction disks. The layers are dried by a stream of nitrogen (10–15 min; ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapour exit. The final analysis is carried out by GC with thermionic detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from two European rivers. With a sample volume of only 2.5 ml, detection limits of 10–30 ppt are achieved in tap water and of 50–100 ppt in river water.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.