Abstract

The effect of winglet height on the thermal-hydraulic performance of finned tube heat exchanger (FTHE) is investigated numerically. The rectangular winglet pairs (RWPs) having 5° attack angle are placed in common flow up (CFU) manner adjacent to the tubes for analysis. The air-side performance evaluation has been done based on the area goodness factor (j/f). The working fluid (air) is considered as incompressible fluid. Additionally, MOORA (multi objective optimization on the basis of ratio analysis) method is employed to get the best performance order of various configurations by taking Nusselt number (Nu) and area goodness factor (j/f) as beneficial attributes and friction factor (f) as a non-beneficial attribute having equal significances. The present study reveals that the rectangular vortex generators having 60 % of the channel height provides the better thermal hydraulic performance compared to the other considered cases.