Abstract
A cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) method was established for the determination of oleanolic acid and ursolic acid in cornel. The two components were separated in the running buffer of 40 mmol/L sodium borate containing 5% methanol, 25 mmol/L SDS and 15 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD). The applied voltage was 24 kV. The wavelength of detection was 200 nm. The temperature was kept at 25 C. Cinnamic acid was used as the internal standard. The analytical performance of the method was tested with respect to linearity, precision and recovery. The calibration curves were linear in the range of 10.15-243.6 microg/mL, r=0.9993 (oleanolic acid) and 10.07-241.7 microg/mL, r=0.9994 (ursolic acid); the intra-day precision (RSD) was less than 3.7% (oleanolic acid) and 4.1% (ursolic acid); the inter-day precision (RSD) was less than 4.2% (oleanolic acid) and 4.9% (ursolic acid). The limits of detection were 1.6 microg/mL for both components. The method proved to be sensitive, rapid, accurate and suitable for the determination of oleanolic acid and ursolic acid in cornel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.