Abstract

A method is developed for the determination of nine organophosphorus pesticide residues in cereals and kidney beans by capillary gas chromatography with flame-photometric detection. In this method, dichloromethane is used for clean-up after liquid-liquid extraction. It is shown that good separations are obtained using a fused-silica capillary column (DB-1701) by the optimized temperature program. In the spiked levels of 0.012-0.43 mg/kg, the recoveries are from 83.7% to 107%, with the relative standard deviation between 3.2% and 13% and limits of detection from 8.2 to 15 microg/kg. The method is rapid, sensitive, and practical.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.