Abstract
Acetylglutamate in HClO 4 tissue extracts is first separated from glutamate by ion exchange. It is then deacylated with aminoacylase, and the resulting glutamate, after adsorption to and elution from an AG 50 column, is quantitated by a fast-HPLC method using o-phthaldialdehyde precolumn derivatization, separation in a C 18 reverse-phase column, and fluorescence detection. A linear response is obtained up to 2 nmol, the detection limit is 5 pmol, and the method is suitable for assay in 1 mg liver tissue and thus for needle biopsies. When samples were analyzed by this procedure and by earlier procedures based upon detection of glutamate with glutamate dehydrogenase or upon activation of carbamoyl phosphate synthetase the results were similar. The method, which is highly specific, compares favorably in sensitivity, precision, and accuracy with all other published procedures. Using this assay, no acetylglutamate has been found in chicken liver and rat kidney.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.