Abstract
Objective To establish the RP-HPLC method for the determination of myricetrin and quercitroside in Euphorbia Hirta L.Methods The ZORBAX SB-C18 (250 mm × 4.6 mm,5 μn) column was used,the mobile phase consisted of acetonitrile:0.1% H3PO4(21 ∶ 79),the flow rate was 0.8 ml/min,the column temperature was 30℃ the detecting wavelength was at 256 nm.Results The cablibration curve was linear within a range of 0.013~0.26 mg/ml and 0.008~0.16 mg/ml,the average recovery was 99.1%,98.9%and the RSD was 0.91%,1.55%,respectively.Conclusion The method is simple,repeatable and accurate,it can be applied in quantitative determination of myricetrin and quercitroside in Euphorbia Hirta L.. Key words: Euphorbia hirta L.; Myricetrin; Quercitroside; RP-HPLC
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.