Abstract
The molecular weight and molecular weight distribution (MWD) of polycarboxylate superplasticizer (PCE) was measured by gel permeation chromatograph (GPC) which combined three different detectors, namely refractive index detector (RI), laser light scattering detector (LS) and viscosity detector (VIS). By conducting numerous experiments, what the different peak stand for in the chromatogram was verified and the best sample concentration range in the GPC experiment was also determined. Besides, based on the analysis to the RI chromatogram, the theory on using peak area ratio to denote concentration ratio was put forward. What’s more, the calculation of macromonomer reaction ratio using the peak area in the RI chromatogram was introduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.