Abstract

<p>Microbial community was determined in a pilot-scale two-stage step-feed biological nutrient removal system treating municipal wastewater with 10 m3 d-1 capacity. Grit chamber effluent at Istanbul Ataköy Biological Wastewater Treatment Plant was used as influent wastewater. In the pilot plant, the influent wastewater was split into two fractions to anaerobic and anoxic2 tank. Nitrosomonas, Nitrosospira, Accumulibacter, and Dechloromonas along with some other uncultured microorganisms were determined in the aerobic, anoxic and anaerobic stages. COD, TN, NH4+-N, TP, PO43--P, SS, and VSS removal efficiencies were found to be 86.7%, 80.3%, 92.5%, 89.5%, 87.5%, 94.8%, and 95.0% in average, respectively, at 5000 mg MLSS L-1 and 15 days of SRT and 16 hours of HRT. The results indicated that microbial community in the process was quite similar with those in the nutrient removal processes with no step feeding. This process can be used cost-effectively to remove carbon and nutrients from medium-strength municipal wastewaters.</p>