A procedure is given for the determination of methylcyclopentadienylmanganese tricarbonyl (MMT) at ng m -3 concentrations in air. The method involves trapping of MMT in a small segment of gas chromatographic column and then determination by gas chromatography with an electrothermal atomic absorption detector. The detection limit of the procedure is 0.05 ng m -3. Air samples from an underground car-park (when MMT was detected) were found to contain between 0.1 and 0.3 ng m -3 MMT. MMT was not detected in any of the street air samples taken.