Abstract
A new derivatization high-performance liquid chromatography method with ultraviolet detection was developed and validated for the quantitative analysis of methanesulfonate genotoxic impurities in an innovative drug for the treatment of non-alcoholic fatty liver disease. In this study, sodium dibenzyldithiocarbamate was used as a derivatization reagent for the first time to enhance the sensitivity of the analysis, and NaOH aqueous solution was chosen as a pH regulator to avoid the interference of the drug matrix. Several key experimental parameters of the derivatization reaction were investigated and optimized. In addition, specificity, linearity, precision, stability, and accuracy were validated. The determined results of the samples were consistent with those obtained from the derivatization gas chromatography–mass spectrometry analysis. Thus, the proposed method is a reliable and practical protocol for the determination of trace methanesulfonate genotoxic impurities in drugs containing mesylate groups.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.