Abstract
A simple, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of antihyperglycemic agent metformin in human plasma using a novel sample extraction procedure. Liquid-liquid extraction of metformin and ranitidine (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (50:50, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a silica column (250 mmx4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (25:75, v/v), pH 6. The limit of quantification (LOQ) was 15.6 ng/ml and the calibration curves were linear up to 2000 ng/ml. The mean absolute recoveries for metformin and internal standard using the present extraction procedure were 98 and 95%, respectively. The intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 8.3%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.