Abstract

An etching technique for the determination of the metallic impurities distribution in silicon wafers has been developed. An area of 10 mmphi and 10 microm depth was etched by 100 microL of an etching solution with a HF and HNO3 mixture. The acid matrix was evaporated on the wafer surface by IR lamp illumination and vacuum exhaust. Metallic impurities remaining on the wafer surface were redissolved into the collection solution, which was measured by electrothermal atomic absorption spectrometry (ET-AAS). The recovery invested by local etching/ET-AAS was within 95 - 112% for Fe, Cu and Ni. The detection limit (3sigma) for Fe, Cu and Ni in silicon was 1 x 10(13) atoms/cm3. To confirm the applicability, local etching was applied to evaluate the effects of metallic impurities in a gettering study and the electronic properties of semiconductor devices. It was found that local etching is a useful sample preparation technique for the analysis of metallic impurities in a specific area on a silicon wafer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.