Abstract
T highly selective and sensitive luminescence methods for the assay of antiinflammatory drug meloxicam (MX) and flufenamic acid (FFA) in biological fluid and tap water are described. The assay of MX was based on europium sensitized luminescence. The method makes use of radiative energy transfer from the enolate ring to europium ions in methanol and in aqueous system. Optimum conditions for the formation of the enolate Eu3+ complexes were investigated. In methanol, the Eu-MX complex was found to depend on the concentration of Tris buffer and Eu3+. In aqueous system, maximum sensitization was obtained in the presence of 0.28% Tween –80, 0.01M tris buffer pH 8.0, 6 mM of 1, 10phenanthroline, 1.75 mM Eu3+ and 7 mM of gadolinium ions as co-luminescence reagent. Under the optimum conditions linear calibration curves between 0-1000 and 0-800 ppb for MX in methanol and in aqueous medium respectively were obtained with the detection limit being 6.0 ppb. The proposed method was successfully applied for the determination of MX in Mobic and Co-Oxicam tablets and in tap water and urine samples. Excellent recovering were obtained for the MX samples. The second method, a novel sequential injection analysis (SIA) approach was used for the determination of FFA in samples of urine and tap water. The method was based luminescence sensitization of terbium by complex formation with FFA. The luminescence signal was monitored at lem = 565nm when excited at lex = 298nm using time resolved mode. Experimental factors that influenced fluorescence reaction were systematically optimized in aqueous medium using chemometric optimization. Under the optimum conditions linear calibration curves between 0-1200 ppb for FFA in aqueous medium were obtained with a LOD of 80 ppb. When applied to Urine and Tap water samples the procedures were found to be free from matrix interferences except for Fe3+ that had significant interference effect. The results obtained for the assay of FFA in urine and tap water samples demonstrated good accuracy and precision. Determination of Meloxicam and Flufenamic Acid in Pharmaceutical Formulations and Biological Fluids using lanthanide Sensitized Luminescence
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Analytical & Bioanalytical Techniques
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.