Abstract

A liquid chromatography-tandem mass spectrometry-based isotope dilution method was developed for the analysis of the triazine compounds melamine (MEL), ammeline (AMN), ammelide (AMD) and cyanuric acid (CYA) in infant formula samples purchased in Canada in 2008 for the purpose of a combined exposure and risk assessment. Infant formula samples were extracted with 1:1 acetonitrile–water, cleaned up on disposable ion-exchange solid-phase extraction cartridges, and analysed by ultra-high-performance liquid chromatography-tandem mass spectrometry. MEL and CYA were detected in almost all infant formula products: the highest concentrations observed were 0.32 mg kg−1 MEL and 0.45 mg kg−1 CYA. Samples that were relatively high in MEL in this survey tended to be low in CYA, and vice versa. Concentrations of AMN and AMD were very low in all samples. The total of MEL-related compounds (sum of all four analytes) in all samples was below the interim standard of 0.5 mg kg−1 for infant formula products established by Health Canada.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call