Abstract

In this work, an experimental system based on digital real-time holographic interferometry for measuring the mass diffusion coefficients of fluid is introduced. The method of processing interference fringe hologram is also introduced thoroughly. By uncertainties analysis and experimental verification, the accuracy of this system is validated. The experimental uncertainties in temperature and mass diffusion coefficient are estimated to be no greater than ± 0.16 K and ± 0.2 %, respectively. On this basis, the mass diffusion coefficients of three fuel additives, diethyl 1,6-hexanedioate (diethyl adipate, DEA), dimethyl carbonate (DMC) and diethyl carbonate (DEC) in air were measured at T = (278.15 to 338.15) K under atmospheric pressure, and polynomial was fitted by the experimental data.