Abstract

Differential pulse anodic stripping voltammetry is applied to differentiate and determine the labile and strongly bound forms of Zn, Cd, Pb and Cu in lake water without preconcentration of the sample. The sensitivities as established for an oxidation peak current of 0·020 μA are: 0·2 ppb for Zn. 0·4 ppb Cd. 0·7 ppb Pb and 0·5 ppb for Cu. For the analysis of a lake water containing 5·0–24·5 ppb of the four metals, the relative S.D. ranged from 1·6 to 10 per cent. Interferences of cations and anions and the choice of a buffer system have been discussed. The method has been applied to study a number of small lakes in the Sudbury area. Ontario.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.