Abstract

A reversed-phase column liquid chromatographic method was developed for analysis of isosorbide dinitrate (ISDN), isosorbide 5-mononitrate (IS5MN) and isosorbide 2-mononitrate (IS2MN) and its pharmaceuticals. Chromatography is performed to Bondclone ODS column using a mobile phase consisting of acetonitrile-PIC B6 buffer, pH 4.75 (13:87) with ultraviolet wavelength at 220 nm. The linearity calibration range was 0.05 mg/ml to 2.5 mg/ml (r = 0.9999), and recoveries were generally greater than 98.0%

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.