Abstract

A method is presented for the determination of isocyanic acid (ICA), HNCO, in air samples as a di-n-butylamine (DBA) derivative. The method is based on sampling in midget impinger flasks containing 10 ml of 0.01 mol l-1 DBA in toluene. Quantification was made using liquid chromatography (LC) and electrospray mass spectrometry (MS) monitoring positive ions. The instrumental detection limit for the LC-MS was 10 fmol of ICA-DBA. ICA was generated by thermal decomposition of urea. A standard solution containing the DBA derivatives of ICA was prepared by collecting the emitted ICA in an impinger flask containing DBA. ICA in the reference solution was characterised by LC and time-of-flight (TOF) MS and quantified by LC chemiluminescent nitrogen detection (LC-CLND). The instrumental detection limit for the LC-CLND was 1 ng of nitrogen. ICA was emitted during thermal degradation of PFU resins and polyurethane (PUR) lacquers, from car metal sheets. ICA was the most dominant isocyanate and in PUR coating up to 8% of the total weight was emitted as ICA and for PFU resins up to 14% was emitted as ICA. When air samples were collected in an iron foundry during casting in sand moulds with furan resins, concentrations of ICA in the range 50-700 micrograms m-3 were found in the working atmosphere.