Abstract

In this study, the polarographic behavior of irbesartan was investigated using the cyclic polarographic method. A mercury drop electrode was used to quantify the peak currents in comparison to Ag/AgCl at 0.10 V/s. Additionally, quick and easy square wave and differential pulse polarographic methods were developed and validated to determine irbesartan in pharmaceutical preparations. For both methods, the calibration curves were linear at concentrations between 5 and 70 μg/mL. The precision was given by relative standard deviation and was less than 2.61%. Accuracy was given with relative error and did not exceed 1.24%. The suggested methods are extremely accurate and precise. No interference was found under the chosen experimental conditions. In pharmaceutical preparations, irbesartan had an average recovery of 99.8%. Therefore, the methods are applicable to the determination of irbesartan in pharmaceutical preparations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.