Abstract
The Authors have developed a novel and easily applicable HPLC method for ifosfamide (IF) determination. This method involves on-line sample processing and its solid-phase extraction by means of an automatic preparator integrated with the chromatographic system. The calibration graph of the method is linear in the concentration range 6-200 μg/ml; minimum detectable concentration is 6 μg/ml. This highly accurate and easily reproducible method was used by the Authors in the treatment of osteosarcoma with slow infusion of ifosfamide.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.