A method has been proposed for the gas-liquid chromatographic determination of 3, 4-dichloropropionanilide (DCPA) in technical products and emulsifiable concentrates. The DCPA was dissolved in toluene and analyzed with added benzyl benzoate (BB) as an internal standard by a Shimadzu Gas Chromatograph GC-2B with a thermal conductivity detector, using helium as carrier gas, the flow rate of which was maintained as 100ml per minute. The column (4mm×1m, stainless steel) used contained 30 weight per cent Apiezon grease L as the stationary phase and 1 weight per cent Emulsogen WS-32 as the tailing reducer on the support of Celite 545 and the column temperature was adjusted to 230°C.A calibration curve in the 0.31.6 weight ratio (DCPA/BB) was found to be almost linear and passed through the zero point. The standard deviation and the mean recovery of the proposed method were calculated to be 1.35%, and 99.9%, respectively for the prepared emulsifiable concentrates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.