Abstract

A new method has been developed for the determination of gold based on separation and preconcentration with a microcolumn packed with nanometer TiO 2 immobilized on silica gel (immobilized nanometer TiO 2) prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of gold, such as pH of the sample, sample flow rate and volume, eluent and interfering ions, have been investigated. Gold could be quantitatively retained by immobilized nanometer TiO 2 in the pH range of 8–10, then eluted completely with 0.1 mol L −1 HNO 3. The detection limit of this method for Au was 0.21 ng mL −1 with an enrichment factor of 50, and the relative standard deviation (R.S.D.) was 1.8% at the 100 ng mL −1 Au level. The method has been applied for the determination of trace amounts of Au in geological and water samples with satisfactory results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.